Key takeaways
- A spinal drape must be sized on the table with the frame in place, since supports add height and width.
- The fenestration is long and narrow, usually with incise film, to match a midline incision and resist retractor pull.
- C-arm access depends on a sterile cover, low stable drape sides and uncluttered flanks.
- Posterior, anterior cervical and lateral approaches need different drape layouts.
Two things define draping for spinal surgery. The first is the patient’s position: for the majority of procedures the patient lies prone on a frame or bolsters, with the back uppermost and the face, airway and lines all underneath. The second is imaging. A C-arm is brought across the sterile field several times in a typical case to confirm the level and to check the position of implants. A spinal drape has to give a long, narrow opening over the spine and still leave the sides of the table free for a machine that swings around it.
This article sets out the main design features and the questions they raise for buyers. Positioning, level marking and the use of imaging are clinical matters decided by the surgical team under hospital protocol.
The prone patient
A prone patient on a spinal frame presents a shape quite unlike the supine abdomen. The trunk is raised on supports so that the abdomen hangs free, the arms are usually brought forward on boards beside the head, and the table may be flexed. The surface to be covered is long, humped and uneven.
This has several effects on the drape:
- Length. The sheet must reach from beyond the head to beyond the feet, with enough at the head end to form a screen for anaesthesia over the arm boards.
- Drop at the sides. Frames add height and width, so a drape sized for a flat table can end above table level once it is laid over one.
- Run-off. The back is a ridge. Fluid leaves the wound sideways and runs down both flanks, not into a dependent hollow.
- Access underneath. The anaesthesia team needs to reach the face, the tube and pressure areas below the drape without lifting the sterile sheet.
The long, narrow fenestration
A midline spinal incision is long in one direction and narrow in the other. The opening in a spinal drape follows it: a rectangular or elongated fenestration aligned with the spine, long enough to allow the incision to be extended by a level or two if needed.
Most designs fill or surround this opening with adhesive. An incise film across the whole fenestration is common, because retractors in a deep spinal wound pull hard on the skin edges and a loose drape edge would be dragged into the wound. Around the opening sits an absorbent, impervious reinforcement that takes the weight of retractor frames, the surgeon’s forearms and instruments.
Where bone graft is to be taken from the iliac crest, a second site is needed. This can be provided by a longer or wider fenestration, by a second opening, or by squaring off with separate sheets, and it should be specified in advance.
Cervical and lumbar procedures compared
“Spinal surgery” covers approaches that have little in common from a draping point of view.
| Procedure type | Usual position | Fenestration | Draping considerations |
|---|---|---|---|
| Posterior lumbar or thoracic | Prone on frame or bolsters | Long, narrow, midline | Side run-off; C-arm access; possible iliac crest site |
| Posterior cervical | Prone with the head held in a clamp or rest | Shorter midline opening high on the sheet | Sealing against the hairline; head fixation under the drape |
| Anterior cervical | Supine with the neck extended | Small opening at the front of the neck | Airway and face close to the field; lateral imaging across the shoulders |
| Anterior or lateral lumbar | Supine or lateral | Abdominal or flank opening | Often draped with a laparotomy-type or split-sheet layout |
| Minimally invasive or endoscopic | Prone | Small opening, sometimes off the midline | Frequent imaging; camera and irrigation tubing; fluid pouch useful |
A single spinal drape will not serve all of these well. Hospitals with a mixed spinal workload usually stock a posterior drape as the standard item and handle anterior approaches with general or head-and-neck drapes.
The C-arm in the sterile field
Imaging is where spinal draping most often goes wrong. For an anteroposterior view the C-arm’s detector sits above the wound; for a lateral view the arm rotates so that the tube and detector are on either side of the patient, one of them passing below the level of the sterile field.
The practical measures are well established, though the details vary between units:
- The part of the C-arm that comes over or near the wound is enclosed in a sterile C-arm cover before it is brought in.
- The drape’s sides must hang low and stay put. A sheet that is taped or weighted to stop it lifting is less likely to be caught and dragged by the arm.
- For lateral views, many teams place an additional sterile sheet along the side of the field, which is brought up over the arm for the exposure and then treated as contaminated and removed or dropped below the field.
- Bulky folds, pouches and tube holders on the flanks should not obstruct the path of the machine.
Three-dimensional imaging and navigation add a reference array fixed to the patient and, in some systems, a ring-shaped scanner that encloses the table. These need their own covers and a drape that does not disturb the array once it is registered. Our article on equipment covers in the sterile field describes the covers themselves in more detail.
Fluid control on a ridge
Open spinal surgery can involve significant blood loss, and irrigation is used generously, particularly when a high-speed drill is cooling bone. Endoscopic techniques use continuous irrigation throughout. Because the wound sits at the highest point of the patient, everything flows outwards and down.
Drape designs respond in two ways. The absorbent reinforcement is extended well out to the sides of the fenestration so that fluid is held before it reaches the edge. And clear collection pouches may be fitted along one or both sides, with drain ports for suction, to catch what the reinforcement cannot hold. Pouches are helpful, but on a spinal drape they must be weighed against the need to keep the flanks clear for imaging; a detachable or low-profile pouch is a reasonable compromise. The underlying principles are covered in our guide to fluid management and strike-through.
What to settle before ordering
- Overall size, checked on your own table with the frame or bolsters in place.
- Length, width and position of the fenestration, and whether it carries an incise film.
- Whether a second opening or extended fenestration is needed for graft harvest.
- The extent of the reinforced zone and the barrier standard and level it has been tested to.
- Pouches: none, one side, both sides, with or without ports.
- Tube holders for suction, diathermy and drill lines, positioned towards the head or foot so that the sides stay clear.
- Whether C-arm covers, an extra side sheet, table covers and gowns are to be included as a pack.
Shrisay Medical manufactures spinal drapes in Faridabad, made to order in size, fenestration and pack configuration; to discuss a design for your spinal theatre, please contact our team.
Frequently asked questions
Why is the fenestration on a spinal drape long and narrow?
It follows the midline incision over the spine and leaves room to extend the wound by a level or two, while keeping as much skin covered as possible.
How is the C-arm kept sterile during spinal surgery?
The part that approaches the field is enclosed in a sterile cover, and many teams add a temporary side sheet for lateral views. The exact method is set by local protocol.
Can one spinal drape be used for anterior cervical surgery?
Generally not. A posterior spinal drape is designed for a prone patient, whereas anterior cervical surgery is done supine through a small opening at the front of the neck.