Key takeaways
- Every pack is checked for integrity, expiry, indicator change and identity immediately before it is opened.
- Unsterile hands touch only the outside of the packaging and sterile hands touch only the contents.
- A circulating nurse opens a wrap away from the body first and towards the body last; a scrubbed nurse does the reverse.
- A wet, damaged or doubtful pack is treated as unsterile, and local policy decides the fate of a dropped one.
Manufacturers go to considerable lengths to deliver a sterile product inside a validated packaging system. All of that work can be undone in the last half metre, between the circulating nurse’s hands and the instrument table. Aseptic presentation is the set of habits that carries the contents of a pack onto the sterile field without the contents touching anything that is not sterile.
The techniques described here are widely taught, but they are general guidance. Hospital policy and the manufacturer’s instructions for use decide the detail.
Checks before a pack is opened
Every pack is inspected immediately before opening, however recently it left the store. The inspection takes seconds and has four parts.
| Check | What to look for | If it fails |
|---|---|---|
| Packaging integrity | Tears, punctures, open or creased seals, crushed corners, water marks or staining | Do not use; set aside and report |
| Expiry date | The use-by date on the label has not passed | Remove from stock under local procedure |
| Sterilisation indicator | The external chemical indicator has changed to the colour stated on the pack | Treat as unprocessed; do not use |
| Identity | Correct product, size and configuration for the case; lot number legible for the record | Return to store and select the right item |
Two points are often misunderstood. An external indicator shows that the pack has been exposed to a sterilisation process; it does not by itself prove that the contents are sterile, which is why integrity and expiry are checked alongside it. And the symbols on the label follow ISO 15223-1, so they read the same way across suppliers. Our guide to reading a sterile medical-device label explains each one.
Who opens what
The roles divide along a simple line: unsterile hands touch only the outside of the packaging, and sterile hands touch only the contents.
- The circulating nurse carries out the checks, opens outer packaging and presents the contents without reaching over the sterile field.
- The scrubbed nurse takes items from the opened packaging, or receives them onto the field, and opens any inner sterile wrap.
Packs are opened as close as practicable to the time of use. Local policy sets how long an opened field may stand and whether it may ever be left unattended.
Peel pouches
Single items such as gowns, individual drapes and equipment covers are usually supplied in peel pouches, with a film or coated-paper face sealed to a backing along a chevron or straight seal. The technique is as follows.
- Hold the pouch away from the body, with the opening end towards the sterile field or the scrubbed person.
- Grip the two free flaps and peel them apart slowly and evenly. A slow peel keeps the seal from tearing and shedding fibres.
- Roll the flaps back over the hands as they separate, so that the hands are behind the packaging and the contents are exposed.
- Present the item for the scrubbed person to lift straight out, without the item sliding across the peeled edges.
The inner line of the seal is treated as the boundary between sterile and unsterile. The contents should not be dragged across the edge of the pouch. Some departments allow light items to be tipped onto the field from a short distance; heavy or sharp items are generally handed over, since a tossed item can roll off the table or pierce a drape. Policy decides which is acceptable.
Wrapped packs
Larger sets, including most procedure kits and packs, arrive in an outer bag with the contents folded inside a sterile wrap. The outer bag is opened by the circulating nurse and the wrapped bundle is placed on a clean, dry table. The wrap is then opened so that nobody reaches across exposed sterile contents.
Flap order for the circulating nurse
- The first flap is opened away from the body.
- The side flaps are opened next, each with the hand on that side.
- The last flap is drawn towards the body, with the person stepping back as it falls.
Each flap is handled by its folded-back tip or outer surface only. Once open, the inner surface of the wrap forms the sterile table cover. Its outer margin is treated as unsterile — a border of about 2.5 cm is commonly taught, though local policy defines it — as is everything hanging below table level.
Flap order for the scrubbed nurse
When a gowned and gloved person opens an inner wrap, the order is reversed: the near flap is opened first, towards the body, so that the gown front is shielded by sterile material before reaching for the far flap. The hands are kept within a cuff of the wrap wherever possible.
A well-designed pack is folded so that the table cover opens in a few movements and the components lie in order of use. This sequencing is one of the practical arguments for custom procedure packs.
Dropped, wet or doubtful packs
The working rule is simple: when sterility is in doubt, the item is treated as unsterile. No case is worth a debate over a single pack.
- Wet packs. Moisture can carry micro-organisms through porous packaging materials. A pack that is wet, or shows a dried water mark, is considered contaminated and is not used. If several packs from one carton or shelf are affected, the batch is quarantined and the store and supplier are informed.
- Dropped packs. Practice differs. Many hospitals discard anything that has fallen to the floor; others allow an item in intact, impervious packaging to be used after inspection. Follow the local policy, and never return a dropped pack to the shelf without that assessment.
- Damaged on opening. If a pouch tears across the contents instead of peeling, or the contents touch the outer surface, the item is discarded and a new one opened.
- Opened but unused. A single-use sterile product that has been opened is not re-wrapped or resterilised by the hospital.
Recurring faults deserve a report to the supplier with the lot number and a photograph. Seal failures and transit damage are usually traceable, and the conditions that cause them are discussed in our article on sterile barrier packaging, storage and handling.
Habits that protect the field
Most lapses in presentation are small and avoidable. A short list covers the majority:
- open packs on a dry surface, with dry hands;
- never reach or lean over an open sterile field;
- keep a safe distance between the unsterile body and the table when presenting;
- do not open packs in a draught or beside an open door;
- record lot numbers where the hospital requires traceability;
- say so at once if contamination is seen or suspected.
Shrisay Medical manufactures sterile procedure packs in Faridabad, with contents and fold sequence configured to order; for a pack arranged around the way your theatre team opens and sets up, please get in touch.
Frequently asked questions
Does a changed indicator mean the pack is sterile?
Not on its own. An external chemical indicator shows that the pack went through a sterilisation process. The packaging must also be intact, dry and within its expiry date.
Can a pack that fell on the floor still be used?
That depends on hospital policy. Many departments discard it; some permit use if the packaging is impervious, intact and clean after inspection. When in doubt, treat it as unsterile.
Why is a wet pack considered contaminated?
Moisture can draw micro-organisms through porous packaging materials and may also weaken seals. A pack that is wet or water-marked is therefore not used.