Key takeaways

  • A 3-ply mask has spunbond outer and inner layers around a meltblown filter layer, and the meltblown does nearly all of the filtering.
  • Standards such as IS 16289, EN 14683 and ASTM F2100 classify masks by bacterial filtration efficiency, differential pressure and splash resistance.
  • Filtration and breathability trade off against each other, and splash-resistant classes are intended for theatre and procedures with spray risk.
  • A surgical mask is loose-fitting and is not a respirator; airborne precautions call for a tested, face-sealing respirator.

Few medical products are as familiar as the pleated three-layer face mask, and few are bought with less scrutiny. Two masks that look identical on the shelf can differ widely in how well they filter, how easily the wearer can breathe through them, and whether they resist a splash of blood. Those differences are invisible to the eye and are established only by testing.

The three layers

“3-ply” refers to three layers of polypropylene non-woven, each with a separate task.

LayerMaterialFunction
OuterSpunbond polypropylene, usually coloured and fluid-repellentSheds droplets and splashes; protects the filter
MiddleMeltblown polypropyleneThe filter: a dense web of very fine fibres that captures droplets and particles
InnerSoft spunbond polypropylene, usually whiteComfortable against the skin; takes up moisture from breath
Nose stripMalleable wire or strip enclosed in the top edgeShapes the mask to the bridge of the nose

The meltblown layer does almost all of the filtering. Its fibres are far finer than those of spunbond, forming a tortuous web, and in many grades the fibres carry an electrostatic charge that helps attract and hold small particles. A mask made from three layers of spunbond alone may look the same and filters far less. The quality of the meltblown is therefore the main thing separating a medical mask from a look-alike; the fabric types are explained in our article on SMS, SMMS and SMMMS non-wovens.

The horizontal pleats let the mask open out to cover the face from the nose to under the chin, and they are worn folding downwards on the outside so that they do not collect droplets.

What the standards measure

Three standards are most often cited for surgical masks: IS 16289 in India, EN 14683 in Europe and ASTM F2100 in the United States. They are built around the same core properties.

Bacterial filtration efficiency

Bacterial filtration efficiency, or BFE, is the proportion of a bacterial aerosol that the mask material stops. In the test, droplets carrying a test organism, with a mean size of roughly three micrometres, are drawn through a sample of the mask, and the number of bacteria passing through is compared with a control. The result is given as a percentage, and all three standards set high minimum values, with the higher classes requiring more.

Differential pressure

Differential pressure measures the resistance of the material to air flow, and so indicates how easy the mask is to breathe through. A lower figure means a more breathable mask. The standards set a maximum because filtration and breathability pull against each other: adding filter media raises BFE and also raises breathing resistance. A mask that is hard to breathe through is uncomfortable, and air then tends to leak around its edges instead of passing through the filter.

Splash resistance

Splash resistance, also called fluid resistance, is tested by firing a small volume of synthetic blood at the outer face of the mask at a defined pressure and checking whether any penetrates to the inner face. The test pressures correspond to the range of human blood pressure, simulating a spurt from a punctured vessel. Not every class of mask is required to pass it.

Other requirements

Depending on the standard, there are further requirements such as microbial cleanliness of the finished mask, filtration of sub-micron particles, flammability and biocompatibility of materials that touch the skin. Buyers should work from the current edition of the relevant standard.

How the classes are arranged

Each standard sorts masks into a small number of classes using these properties, and the logic is similar across them.

  • EN 14683 defines Type I, Type II and Type IIR. Type II requires higher bacterial filtration than Type I. The “R” in Type IIR indicates that the mask also meets a splash resistance requirement.
  • ASTM F2100 defines three levels, with the higher levels requiring greater fluid resistance and higher filtration.
  • IS 16289 likewise divides surgical masks into classes with requirements for bacterial filtration, breathability and splash resistance.

The numerical limits differ between the documents and have been revised over time, so a class in one system should not be assumed to equal a class in another. In practical terms, masks without splash resistance are suited to general use and to limiting droplets from the wearer, while splash-resistant classes are intended for theatre and for procedures where spray of blood or body fluid is possible. Hospital policy decides which class is required where. In India, masks are regulated as medical devices; the framework is outlined in our article on how surgical products are regulated in India.

Ear-loop or tie-on

  • Ear-loop masks are quick to put on and remove, which suits wards, outpatient areas and visitors. Fit depends on the loop length matching the wearer’s face, and loops can become sore behind the ears over a long shift.
  • Tie-on masks have four tapes, tied at the crown and at the nape. They take longer to put on but can be adjusted to any head size, hold their position over hours, and sit comfortably with a theatre cap. They are the traditional choice for the scrubbed team.

Either type must be shaped at the nose, pulled down under the chin, and removed by the loops or ties without touching the front.

A surgical mask is not a respirator

The most important limitation concerns fit. A surgical mask is loose-fitting by design. However good the filter material, some air passes around the edges at the cheeks and nose when the wearer breathes in. The mask is designed mainly to catch what the wearer breathes out and to shield the face from splashes and large droplets.

A respirator, such as those certified as N95 or FFP2, or under the Indian Standard for filtering half masks, is built to seal against the face and is tested for filtration of fine particles and for inward leakage, with fit testing of the individual wearer where policy requires it. Where airborne precautions or aerosol-generating procedures are involved, hospital policy will call for a respirator, and a 3-ply mask is not a substitute.

Wearing, changing and buying

  • Clean hands before putting the mask on and after taking it off.
  • Wear the coloured, fluid-repellent side outwards with the nose strip at the top.
  • Change the mask when it is damp, soiled or damaged, and between cases in theatre.
  • Do not wear it under the chin or carry it in a pocket for reuse.

When purchasing, ask which standard and class the mask is certified to, request a recent test report from an accredited laboratory covering filtration, differential pressure and, where claimed, splash resistance, and confirm that the report relates to the product being supplied.

Shrisay Medical manufactures the 3-ply face mask in Faridabad for hospitals, distributors and export buyers; for specifications and samples, please contact our team.

Frequently asked questions

What does the “R” in Type IIR mean?

In EN 14683 the “R” shows that the mask has passed a splash resistance test with synthetic blood, in addition to meeting the filtration and breathability requirements of Type II.

Can a 3-ply surgical mask be used in place of an N95 respirator?

No. A surgical mask does not seal to the face, so air leaks around its edges. Where airborne precautions apply, a certified respirator is required under hospital policy.

Which is better, an ear-loop or a tie-on mask?

Ear-loop masks are quicker for short wear and general areas. Tie-on masks adjust to any head size and stay in place over long procedures, so they are often preferred in theatre.

Sourcing accessories & apparel? Send us your specification or a reference sample and we will respond with product details and pricing.
Request a quote
← All articles