Key takeaways
- Surgical drapes and gowns are medical devices in India and fall under the Medical Devices Rules, 2017, administered by CDSCO together with State Licensing Authorities.
- Regulatory licensing and BIS product certification are separate systems: one concerns legal permission to manufacture or import, the other conformity to an Indian Standard.
- QCI, GeM, MSME and similar registrations have their own purposes and should not be read as product approvals.
- Rules and notifications are amended regularly, so the current position should always be confirmed from official sources.
A supplier profile for an Indian manufacturer of surgical consumables usually carries a row of logos: CDSCO, BIS, QCI, GeM, MSME and others. Each represents a different body with a different job, and only some of them are regulators. For a hospital purchase officer or an overseas importer trying to judge a supplier, it helps to know which is which. This article gives a general map of how surgical drapes and gowns are regulated in India. The framework has been amended many times and continues to evolve, so treat this as orientation and confirm specifics against current notifications or with a regulatory adviser.
The legal foundation: the Medical Devices Rules, 2017
Medical devices in India are regulated under the Drugs and Cosmetics Act, 1940. The Medical Devices Rules, 2017, made under that Act, set out a dedicated framework for devices covering classification, licensing of manufacture and import, quality management, labelling, clinical investigation and post-market duties. The scope of what counts as a regulated medical device was subsequently widened by notification so that devices in general, not only a short notified list, came within the system through a phased transition.
Surgical drapes and gowns are intended for use in surgical procedures to limit the transfer of infective agents, and they are treated as medical devices. A manufacturer or importer therefore needs to hold the appropriate permission for the products it supplies.
Risk classes and who issues the licence
The Rules classify devices into four classes by risk: Class A (low), Class B (low moderate), Class C (moderate high) and Class D (high). The class determines both the depth of scrutiny and the authority involved.
- Manufacture of Class A and Class B devices is licensed by the State Licensing Authority of the state in which the factory is located.
- Manufacture of Class C and Class D devices is licensed by the Central Licensing Authority.
- Import of devices is dealt with by the Central Licensing Authority.
The Central Drugs Standard Control Organisation (CDSCO) is the national regulatory body and functions as the Central Licensing Authority. It also publishes classification lists for categories of device. Drapes, gowns and similar non-invasive surgical consumables generally sit in the lower risk classes, but the class of a specific product should be confirmed from CDSCO’s published classification and the manufacturer’s licence, particularly as the treatment of sterile and non-sterile low-risk devices differs.
Licensed manufacturers are required to operate a quality management system as laid down in the Rules, and applications and approvals are handled through the regulator’s online portal.
BIS: standards and the Standard Mark
The Bureau of Indian Standards (BIS) is the national standards body. It does two things relevant here. First, it publishes Indian Standards, including IS 17334:2019 for surgical gowns and surgical drapes and other standards in the medical textiles series. Second, it runs conformity assessment schemes under which a manufacturer can obtain a licence to apply the Standard Mark to a product that conforms to a particular Indian Standard.
BIS certification is product-specific and standard-specific. It is in principle voluntary, but the Government can make conformity to particular standards compulsory through Quality Control Orders. Because such orders are introduced, extended and revised from time to time, the status for a given product should be checked when a tender is drafted.
The key point is that a BIS licence and a medical device manufacturing licence answer different questions. One says the product conforms to a named standard under a certification scheme. The other says the manufacturer is legally permitted to make the device.
The bodies at a glance
| Body or system | Role | What it means when you see it |
|---|---|---|
| CDSCO | National medical device regulator; Central Licensing Authority | The manufacturer or importer is within the regulatory system for the devices named in its licence or registration |
| State Licensing Authority | Licenses manufacture of lower-risk classes in its state | A manufacturing licence for specified devices at a specified site |
| BIS | National standards body; product certification | A licence to use the Standard Mark on a named product against a named Indian Standard |
| QCI | Quality Council of India; its boards accredit laboratories and certification bodies and it operates quality schemes | Depends on the scheme; look at what exactly has been certified or accredited |
| GeM | Government e Marketplace, the public procurement portal | The seller is registered to supply government buyers, for example as an OEM; it is not a product approval |
| MSME, NSIC, FIEO and similar | Enterprise registration, small-industry support and export promotion | Business status and eligibility for certain benefits; not evidence of product quality |
Labelling, sterility and disposal
The Medical Devices Rules contain labelling requirements for devices sold in India. In general these include the name of the device, the manufacturer’s name and address, the licence number, the lot or batch number, dates of manufacture and expiry where applicable, and an indication of sterility and single use where relevant. Packaged goods may also be subject to legal metrology declarations. Sterilisation and packaging are expected to be validated under the manufacturer’s quality system, using the recognised standards for the process concerned.
After use, drapes and gowns contaminated with blood or body fluids become biomedical waste. Their segregation, treatment and disposal by healthcare facilities are governed by the Bio-Medical Waste Management Rules, 2016, which are environmental rules separate from device regulation.
What this means for a buyer, and what to ask
For a domestic buyer, a sensible order of checks is as follows:
- Ask for the medical device licence or registration and confirm that it lists the product category and the manufacturing address.
- Where the tender requires an Indian Standard, ask for the BIS licence or for test reports from an accredited laboratory, as the tender specifies.
- Check the label of a sample pack against the particulars above.
- For government purchases, confirm the seller’s GeM status and whether it is listed as the manufacturer or as a reseller.
Overseas importers should remember that Indian licensing does not replace the requirements of the destination market. Shrisay Medical is a GeM-registered OEM manufacturing in Faridabad, with several products BIS certified; our quality and certifications page lists the registrations displayed on this site, and documents for a specific product can be requested through the contact page.
Frequently asked questions
Are surgical drapes and gowns medical devices in India?
Yes. They are treated as medical devices and fall within the Medical Devices Rules, 2017. The applicable risk class and licensing route should be confirmed from current CDSCO classification.
Is BIS certification mandatory for surgical gowns and drapes?
BIS certification is voluntary unless made compulsory for a product by a Quality Control Order. The position can change, so check the current status and the requirements of your tender.
Does GeM registration mean a product is approved?
No. GeM is a procurement platform. Registration shows the seller can supply government buyers; product compliance is shown by licences, certifications and test reports.