Key takeaways

  • Controlled manufacturing keeps bioburden and particles low and consistent, so that the product reaches sterilisation within validated limits.
  • ISO 14644-1 classifies air cleanliness by particle concentration, and a class is meaningful only with its occupancy state.
  • People are the main source of contamination, which makes gowning, behaviour and training central to control.
  • Environmental monitoring and product bioburden testing link the condition of the room to the sterility claim on the label.

A common assumption is that the conditions under which a drape or gown is made hardly matter, because the sealed pack is sterilised at the end. The reasoning is flawed in two ways. A sterilisation process is validated against an assumed level of microbial contamination, and it performs as intended only if the product arrives within that level. And sterilisation kills micro-organisms; it does not remove dust, fibres, hair or the remains of dead bacteria. A product has to be clean before it is made sterile, and that is the purpose of manufacturing in a controlled environment.

What a controlled environment is for

For terminally sterilised products the aims are specific and limited.

  • Low and consistent bioburden. The population of viable micro-organisms on the product before sterilisation should stay within the range assumed when the process was validated.
  • Control of particles. Lint and dust sealed into a pack will be released over the wound when the pack is opened. The clinical significance is discussed in our article on lint and particles in the theatre.
  • Exclusion of foreign matter and pests. Hair, insects and stray fragments of packaging are among the most serious complaints a sterile product can attract.

The aim is not asepsis. These products are not made sterile by the room; the room keeps the challenge to the sterilisation process small and predictable. ISO 13485 expects a manufacturer to document the work environment its products require and, for sterile devices, to control contamination during assembly and packaging.

ISO 14644-1 classification in outline

ISO 14644-1 classifies the cleanliness of air in clean rooms and clean zones by the concentration of airborne particles. It defines a scale of classes from ISO Class 1 to ISO Class 9, in which a lower number means cleaner air, and each class sets maximum permitted concentrations of particles at and above specified sizes. A step of one class corresponds to a tenfold change in the permitted concentration.

Several points help in reading a claim based on this standard.

  • It counts particles, not microbes. Classification says nothing directly about viable organisms, which are monitored by separate methods.
  • The occupancy state matters. A room may be classified as built, at rest, or in operation with people and machines working. A class quoted without the state is incomplete, since people are the main source of particles.
  • Classification is periodic; monitoring is continuing. ISO 14644-2 deals with monitoring to show that the room continues to perform between formal classifications.
  • The class is the manufacturer’s choice. No single class is prescribed for converting drapes and gowns. Classes at the less stringent end of the scale, such as ISO Class 7 or ISO Class 8, are commonly cited for assembling and packing devices that will be terminally sterilised, with the selection justified by risk.

Cleanliness is achieved by supplying filtered air, typically through high-efficiency filters, in sufficient volume to dilute and carry away what is generated in the room, and by using smooth, cleanable surfaces for walls, floors and work tables.

Pressure cascades and zoning

Clean air is kept clean by making it flow outwards. The cleanest room is held at a slightly higher air pressure than the area beside it, and that area higher than the one beyond, so that whenever a door opens, air moves from clean to less clean. This sequence of stepped pressures is called a pressure cascade.

A typical layout moves from uncontrolled areas, such as the raw-material warehouse, through intermediate zones to the controlled area where product is exposed. Airlocks sit at the boundaries, with doors arranged so that both sides are not open at once. Differential pressures are displayed on gauges and recorded, and a loss of pressure is treated as an event to be investigated.

People: gowning and behaviour

People shed skin particles, hair and micro-organisms continuously, and more so when they move. Personnel controls are therefore the core of any contamination control programme.

  1. Entry through a change room, often divided by a step-over bench into a street-clothes side and a clean side.
  2. Removal of outer clothing, jewellery and personal items, in line with the site’s rules.
  3. Hand washing and sanitising before putting on clean-room garments.
  4. Dedicated garments: head cover enclosing all hair, beard cover where needed, face mask, coat or coverall, and dedicated footwear or shoe covers. Gloves are worn where product is handled directly.

Behaviour matters as much as clothing. Eating, drinking and cosmetics are excluded from controlled areas, movement is kept deliberate.

Material flow and cleaning

Materials can carry as much contamination as people. Fabric rolls and packaging usually arrive in cartons and outer wraps that have travelled by road and stood in a warehouse. Cardboard and wooden pallets shed fibres and can harbour pests, so they are normally kept out: outer packaging is removed in a de-boxing area and rolls pass through a material airlock on clean trolleys or plastic pallets.

Inside, the flow is arranged to run in one direction, from cutting through assembly and folding to primary packing, so that finished product does not cross the path of incoming material. Cleaning follows a written schedule that specifies agents, methods and frequencies for floors, surfaces and machines, and records are kept.

What is monitored

ParameterHow it is monitoredWhat it shows
Airborne particlesParticle counter at defined locations and intervalsWhether the room continues to meet its class
Differential pressureGauges or sensors between zones, read or logged routinelyWhether air is flowing in the intended direction
Temperature and humidityCalibrated instruments, loggedStability of working and process conditions
Airborne micro-organismsSettle plates and active air samplersViable contamination in the air
Surfaces and personnelContact plates or swabs of work surfaces, equipment and glovesEffectiveness of cleaning and gowning
Product bioburdenLaboratory testing of pre-sterilisation samples to ISO 11737-1The actual microbial load presented to sterilisation

Each parameter has alert and action limits set by the manufacturer. Trends matter more than single readings: a gradual rise in counts points to a deteriorating filter, a lapse in cleaning or a change in practice well before any limit is breached.

What a buyer can ask or observe

  • Which operations take place in the controlled area, and where primary packing is sealed.
  • The classification claimed, the occupancy state it refers to, and the date of the last classification report.
  • How bioburden is monitored and how results compare with the limits used in validation.
  • On a visit: how visitors are gowned, whether cardboard is present in the clean area, and whether doors are kept closed.

The questions sit naturally within a wider review of the quality system, as described in our article on what ISO 13485 tells a buyer.

Shrisay Medical manufactures surgical drapes, gowns and procedure packs in Faridabad; an outline of the stages involved is given on our manufacturing process page, and further questions may be sent through our contact page.

Frequently asked questions

If the product is sterilised anyway, why does the manufacturing environment matter?

Sterilisation is validated for a defined microbial load and does not remove particles or dead organisms. A controlled environment keeps the product clean and within the limits the process was designed for.

Does an ISO 14644-1 class tell me about bacteria in the room?

Not directly. The classification is based on airborne particle counts. Viable organisms are monitored separately with settle plates, air samplers and surface sampling.

Which clean-room class is required for making surgical drapes?

No single class is prescribed. The manufacturer selects and justifies a class on the basis of risk, and should be able to state the class, the occupancy state and the date of the last classification.